Home Heat Loss & Heating Load Calculator

Estimate design heat loss in BTU/hr from U-value, area, ΔT, air infiltration, plus annual heating energy and cost.

Your files stay on this device

Files are processed in your browser, never uploaded. The site downloads code and assets to run the tools. No accounts or trackers.

Use Download to save this tool as one HTML file for offline use.

Privacy →

Optional air infiltration:

Optional annual energy & cost:

About this tool

Home Heat Loss & Heating Load Calculator is a free, in-browser tool that estimates how fast a room or home loses heat and how much that costs to replace over a season. It uses the real U · A · ΔT engineering model rather than a rule-of-thumb, and every figure is computed locally as you type.

Conductive loss through a surface is Q = U · area · ΔT, where U is the assembly U-value (or 1 / R if you enter an R-value), area is the surface size and ΔT is the indoor-minus-outdoor design temperature difference. Add optional air-infiltration loss from air changes per hour and room volume (0.018 · ACH · volume · ΔT in imperial, 0.33 · ACH · volume · ΔT in metric) to get the total design load in BTU/hr and kW. Both imperial and metric inputs are supported.

Enter heating degree days (HDD), a system efficiency and an energy price and it projects the annual heating energy (kWh) and cost, converting to per-kWh, per-therm or per-cubic-metre fuel. Use it to size a furnace or heat pump, compare insulation upgrades, or estimate a winter heating bill.

Frequently asked questions

What is ΔT and what value should I use?
ΔT is the difference between your indoor design temperature and the outdoor design (coldest expected) temperature. For example a 70°F indoor and 30°F outdoor gives ΔT = 40°F. In metric use the same difference in °C. Larger ΔT means proportionally more heat loss.
How do I find my U-value or R-value?
Use the R-Value / U-Value calculator to build up an assembly, read a manufacturer's rated U-value, or use typical values — an insulated wall is roughly U-0.06 to U-0.10 (R-10 to R-17). Switch the mode to enter whichever number you have; the tool converts R to U automatically.
What are heating degree days (HDD)?
HDD sum how far and how long outdoor temperature stays below a base (typically 65°F / 18°C) over a year, so they capture how cold your climate is. Annual heat energy is UA · 24 · HDD, where UA is your total loss divided by ΔT. Look up your location's HDD from a weather service and enter it to get an annual estimate.
Does this size my furnace exactly?
It gives a solid design heat loss you can match to equipment output, but a full Manual J load also accounts for windows, orientation, internal gains and duct losses individually. Treat the total as a well-grounded estimate and add a modest safety margin, not an oversized one.