UTILS.
Private by default
🌊

Salinity & Specific Gravity Converter

Convert between salinity (ppt), specific gravity, and conductivity for marine tanks, with hydrometer temperature correction to 25 °C.

Your files stay on this device

Files are processed in your browser, never uploaded. The site downloads code and assets to run the tools. No accounts or trackers.

Use Download to save this tool as one HTML file for offline use.

Privacy →

Enter one of salinity, specific gravity, or conductivity plus the sample temperature to get the other two at 25 °C.

About this tool

The Salinity & Specific Gravity Converter is a free, in-browser tool that translates any one of the three ways marine aquarists measure salt content — salinity in ppt, specific gravity, or conductivity in mS/cm — into the other two. It uses the standard 25 °C/77 °F reference where 35 ppt = SG 1.0264 = 53.0 mS/cm. Enter one value plus the sample temperature and it outputs the rest at the 25 °C reference. Everything is computed locally in your browser, so nothing you enter is uploaded.

The practical relations are salinity (ppt) = (SG_25 − 1) ÷ 0.000754, its inverse SG_25 = 1 + ppt × 0.000754, and conductivity (mS/cm) ≈ ppt × 1.514 across the seawater range of about 25–40 ppt. Glass hydrometers are calibrated at a fixed temperature (usually 25 °C), and seawater density falls by roughly 0.00025 SG per °C as it warms, so a hydrometer reading taken warm reads low. The tool corrects specific-gravity input to the 25 °C reference with SG_25 = SG_measured + 0.00025 × (T_sample − T_calibration) before converting. It also flags target bands: fish-only tanks run about 30–34 ppt and reef tanks about 33–35 ppt.

As a worked example, a swing-arm hydrometer reads SG 1.026 in a sample at 27 °C, calibrated at 25 °C. The corrected value is 1.026 + 0.00025 × (27 − 25) = 1.0265, which is (1.0265 − 1) ÷ 0.000754 ≈ 35.1 ppt and about 53.2 mS/cm — solidly in the reef range. Note that refractometers and conductivity meters with automatic temperature compensation already report the 25 °C value, so for those instruments leave the sample temperature at the calibration temperature.

Frequently asked questions

How do salinity, SG, and conductivity relate?
At 25 °C, 35 ppt = SG 1.0264 = 53.0 mS/cm. Salinity (ppt) = (SG − 1) ÷ 0.000754, and conductivity (mS/cm) ≈ ppt × 1.514. The tool converts any one input into the other two at that reference.
Why correct a hydrometer reading for temperature?
Seawater density drops about 0.00025 SG per °C of warming, and glass hydrometers are calibrated at one temperature. A warm sample reads low, so the tool applies SG_25 = SG_measured + 0.00025 × (sample − calibration) before converting.
Do I need temperature correction for a refractometer?
Usually not. Most aquarium refractometers and conductivity meters have automatic temperature compensation and already display the 25 °C value. Enter the salinity or conductivity directly and set the sample temperature equal to the calibration temperature.
What salinity should my tank be?
Fish-only marine tanks typically run 30–34 ppt (SG ≈ 1.0226–1.0256), while reef tanks with corals prefer 33–35 ppt (SG ≈ 1.0249–1.0264), matching natural seawater. The tool shows which band your value falls into.

More tools