Wet-Bulb Temperature Calculator

Find the wet-bulb temperature — the lowest temperature reachable by evaporative cooling — from air temperature and relative humidity.

Your files stay on this device

Files are processed in your browser, never uploaded. The site downloads code and assets to run the tools. No accounts or trackers.

Use Download to save this tool as one HTML file for offline use.

Privacy →

Stull approximation — most accurate near sea-level pressure and RH 5–99%.

About this tool

The Wet-Bulb Temperature Calculator estimates the wet-bulb temperature (Tw) — the temperature a parcel of air would reach if cooled to saturation by evaporating water into it at constant pressure. It is the reading a thermometer wrapped in a wet wick shows in a moving airstream, and it sets the hard physical limit on how much cooling sweat or a swamp cooler can deliver. A sustained wet-bulb near 35°C is considered the survivability threshold for humans.

This tool uses the Stull (2011) empirical formula: Tw = T·atan(0.151977·√(RH+8.313659)) + atan(T+RH) − atan(RH−1.676331) + 0.00391838·RH^1.5·atan(0.023101·RH) − 4.686035, with temperature T in °C, relative humidity RH in %, and the arctangents evaluated in radians. It is accurate to within a few tenths of a degree near standard sea-level pressure (1013.25 hPa) for RH between 5% and 99% and T from −20°C to 50°C.

Everything runs locally in your browser — no data leaves the page. Enter the air temperature (°C or °F) and relative humidity; the result is shown in both °C and °F along with the wet-bulb depression (the gap between dry-bulb and wet-bulb temperature), which widens as the air gets drier. Accuracy degrades at high altitude or far from standard pressure.

Frequently asked questions

What is wet-bulb temperature?
It is the lowest temperature air can reach through evaporative cooling alone. Because evaporation stops once the air is saturated, the wet-bulb temperature caps how effective sweating or evaporative coolers can be — a key heat-stress metric.
Which formula does this use?
The Stull (2011) single-equation approximation from air temperature and relative humidity. It is valid near standard sea-level pressure for RH 5–99% and temperatures of −20°C to 50°C, matching iterative psychrometric solutions within a few tenths of a degree.
Why is wet-bulb near 35°C dangerous?
The human body sheds heat by evaporating sweat. When the wet-bulb temperature approaches skin temperature (~35°C), evaporation can no longer cool the body, so core temperature rises even at rest — a fatal condition without cooling.
Is this the same as the dew point?
No. The dew point is the temperature at which water vapor condenses at constant pressure; the wet-bulb temperature accounts for evaporative cooling and always lies between the dew point and the dry-bulb (air) temperature.